Product

Lab Equipment

  Page: 1, 2    Next


WATER BATH
Made of stainless steel. Complete with electrical to work on 220 /230 volts A.C.

WxDxH (mm)  
300x250x100 ( 6 Holes of 75 mm dia.)  
325x325x100 ( 9 Holes of 75 mm dia.)  
405x355x110 (12 holes of 75 mm dia.)  


PLANT GROWTH CHAMBER
Double walled outer body made of M.S duly painted and inner chamber made of S.S.

WxDxH (mm) Capacity/CFT Trays  
505 x415 x830 6 2  
570 x505x875 10 3  
650x560x900 12 3  
700x650x900 14 4  


OVEN
Double walled outer body made of M.S body duly painted and inner chamber made of S.S.

WxDxH (mm)  
300x300x300  
355x355x355  
455x455x455  
455x455x600  
600x600x600  

.


HORIZONTAL AUTO CLAVE
APCON'S Autoclaves are reliable enough for buying peace of mind. The inner and outer chamber is made of high grade stainless steel.

Size Dia*Depth(mm ) Load  
250x450 3 KW  
300x500 3 KW  
350x550 4 KW  
400x600 4 KW  
450x650 4 KW  
550x750 6 KW  
400x1100 9 KW  


MUFFLE FURNACE
Light weight muffle furnace max. Temp. Range 1000° C and working temp. 900° C.

Muffle Size  
4'' * 4'' * 9''  
5'' * 5'' * 10''  
6'' * 6'' * 12''  
8'' * 8'' * 12''  


HUMIDITY CHAMBER
This unit is provided with digital temperature controller com Humidity controller cum indicator to control and display temperature from 5° C to 50° C +/-1° C and humidity range above atmospheric humidity level to 90% to +/-5% R.H. Complete with electrical to work on 220/230 volts A.C.

Size (mm) No. of Shelves  
710 *455 *455 2  
605 *605 *605 3  
910 *605 *605 3  


INCUBATOR
Double Wall construction having inner working chamber and shelves made of stainless steel and outer body made of mild steel, elegantly finished in powder coating paint.

WDH (mm) Capacity Trays  
455 x 410 x 610 112 2  
505 x 415 x 830 171 2  
570 x 550 x 875 280 3  
650 x 580 x 900 336 3  
700 X 640 X 900 420 3  
HOT PLATE

Size (mm)    
25 * 30 * 15    
25 * 40 * 15    
30 * 45 * 15    
45 * 60 * 15    
MAGNETIC STIRRER

Capacity    
1 to 2 Liters    
5 Liters    
10 Liters    


AUTOCLAVE
The unit has inner chamber, outer body, lid, ring, radial locking system all made of
stainless steel provided with automatic pressure control switch. Low water level
cut-off device, pressure gauge, Dial thermometer, safety valves, timer, S.S. Basket
vacuum breaker and 0.60 minutestimer.2
Size Dia. * Depth (mm)

a) 250 * 450 39,000
b) 300 * 300 44,000
c) 350 * 600 49,000
d) 400 * 600 54,000
e) 450 * 600 58,000
f) 550 * 750 67,500


NITROGEN GENERATOR
Principle Specifications LC-MS LC-MS-MS Turbo Evaporator
Moisture 5ppm 5ppm 50-200ppm
Total Hydro Carbon <1ppm <1ppm <15ppm
Co & Co2 <2ppm <2ppm <10ppm
Purity 99.9% 99.9% >98%
Micro Particulate <0.01µ <0.01µ <0.01µ
Capacity of N2 Generator 6 to 30 LPM at 100 psig(as per selection of model) 12LPM at 100psig
8LPM at 60psig
4LPM at 60psig
50 to400 LPM AT 60 psig
Method of Purification PSA PSA PSA
Room temperature 5°C-25°C 5°C-25°C 5°C-25°C
Start up time 1hrs 1hrs/programmable timer 1hrs
Electrical requirements without Compressor 230 VAC, 50HZ, 1AMP 230 VAC, 50HZ, 1AMP 230 VAC, 50HZ, 1AMP
Dimension of N2 Generator in mtr.(without compressor) 1.5H¤0.8W¤0.8D 2H¤1W¤1D 1.5H¤0.8W¤0.8D
Net Weight(without compressor) 100Kg-200kg 100Kg-200kg 100Kg-200kg


LAMINAR FLOW CABINET
Delux model with infilco hepa filter with certified test report and 2 Year Warranty and stainless
steel work table. Other specifications same as in, HORIZONTAL LAMINAR AIR FLOW TABLE

Size

a) 2' * 2' * 2'
b) 3' * 2' * 2'
c) 4' * 2' * 2'
d) 6' * 2' *2'
ULTRASONICATOR
Operating frequency 33± 3khz, for all general purpose cleaning is highly recommended. Input voltage range of 170V AC-270V AC, 50 Hz, 1ph. Micro Controller based timer range 0 to 30/99 minutes Thermostatic Controlled temperature controller.
 AAS / ICP Hood
This is useful for removing toxic fumes generated in AAs or ICP applications. It is specially designed for fulfilling basic requirements of AAS* or ICP** installation. These hoods are mounted directly on torch of AAS / ICP unit.

Some of the important points are :-
a) Made of Stainless Steel 304 grade.
b) Airflow control valve to regulate airflow.
c) High efficiency centrifugal blower for suction.
d) Custom built, maintenance-free design.
GAS PURIFICATION & CONTROL SYSTEM
Application Filter type Min inlet Impurity level Max outlet Impurity level Length Capacity
Moisture removal Silica gel/Molecular 20ppm <3ppm 10" 210CC
Hydro Carbon Removal Activated Charcoal/Carbon 10ppm <2ppm 10" 210CC
Oxygen Removal De-Oxo Chemical catalyst 10ppm <2ppm 8" 125CC
Particle Removal Micron filter 25µ <0.5µ 2"